Fan motor out don't work 2000 cherokee
WebAug 22, 2013 · Check this fuse first. You can check to see if the fan works with an overtemp situation. Detach the connector fron the Engine Coolant Temperature sensor and jumper the harness connector with a 470 Ohm resistor - key ON, engine off. This will simulate approximately 235*F coolant temp and put the fan on. (see pic below). WebDec 13, 2014 · The contact owns a 2000 Jeep Cherokee. While driving 55 mph, there was a loss of transmission power. The vehicle hesitated excessively, but the engine continued to operate. The warning...
Fan motor out don't work 2000 cherokee
Did you know?
WebJan 9, 2024 · Tighten all screws to stop vibration noises. If the problem was a buzzing noise, you might not need a new motor. Check the fan and motor assembly, the housing the … WebSep 14, 2012 · 1.disconnect battery and remove. 2. disconnect computer and remove. 3. remove 3 8mm bolts. 4. disconnect blower motor from pigtail. 5. pull motor out. It took no longer than 15 minutes. Of course then I had to repair the melted parts in the control area which took longer. Mine is a 2000 sport 4.0L.
WebDec 30, 2008 · There is a fan switch, a resistor, a fan motor and the wires for them. If the fan did work, or you apply 12V to the fan and it works, that just leaves the other three. … WebJan 26, 2024 · Conclusion. Car fans staying on after the engine is turned off may be caused by several reasons, such as low coolant level, malfunctioning cooling system, still-on A/C …
WebApr 5, 2010 · Sutherngal64 April 5, 2010, 1:10pm 1. My radio, windshield wipers and ac/heater fan will not work. It will however work when you turn the key all the way back or forward but not when the engine is running. Not sure if it is a fuse problem or not. It is a 2003 and has 176,xxx miles on it. missileman April 5, 2010, 1:39pm 2. It’s not a fuse ... WebNov 9, 2012 · There are two primary items that would be common to a problem at all speeds, the fan speed switch and the fan motor itself. The resistor pack is not in the …
WebFeb 5, 2015 · Obviously, too much current draw was causing the wires to heat up. When I pulled the blower fan, it would only free spin about one turn with a lot of drag. I replaced …
WebFeb 9, 2024 · The answer to everyone's question is the blower motor module/resistor. Check for bad fuse and relay, if they check out move under the dash with a test light. Check your power and grounds, if they check good and you still want to … my bt track orderWebOct 1, 2009 · Basics First. Twist the ignition key to accessory (ACC) mode and turn the fan switch to high. Back-probe the hot line into the fan, and you should see 12 volts in the … my bt track faultWebSep 5, 2024 · You have replaced 90% of the relevant parts but without the fan coming on it will definitely keep overheating. The only part you did not replace to make the fan run is the temperature sensor which kicks the fan on when coolant is hot. Now there are TWO temp sensors. One gives you a temp gauge reading. The other is the one that turns on the fan. my bttv accountWebMay 18, 2012 · Re: 2000 Cherokee 4WD 4.0 Backfiring through Intake. Pull the cam sensor drive (you will have to re align it when you reinstall it) and check the teeth on the cam and sensor drive. Before you pull it see how it lines up. Bring #1 up to TDC on the compression stroke, pull the sensor off and see if the hole in the drive rotor lines up with … my bt tv app for windows 10Webthere are resistors by the blower motor check them since you only could operate it on high those coil resistor are probably bad. tap the blower lightly see if it starts, check all relays … my bt tv onlineWebAug 9, 2024 · Discussion Starter · #1 · Dec 15, 2007 I have a 96 Grand Cherokee LTD. The blower fan won't shut off, even if the car is shut off and key is out of ignition. The only way to shut it off is to remove the 40A fuse that is in the fuse block under the engine hood. mybtu cottbusWebFeb 28, 2016 · I have a 2000 TJ, and one fan speed doesn't work. Odd. I'll repost if I figure it out. When just one fan speed doesn't work, that is typically caused by the resistor pack. When no fan speeds work, it is probably the fan speed switch or a fried wiring harness as happens on older TJs. -When you have a choice, buy American. S sport01 Registered my btu account login